{"id":5099,"date":"2023-08-29T12:15:23","date_gmt":"2023-08-29T03:15:23","guid":{"rendered":"http:\/\/133.125.84.183\/en\/?page_id=5099"},"modified":"2023-10-02T15:08:35","modified_gmt":"2023-10-02T06:08:35","slug":"center","status":"publish","type":"page","link":"http:\/\/133.125.84.183\/en\/center\/","title":{"rendered":"Evaluation Center"},"content":{"rendered":"\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\">Have credible analytical and analytical power<br>Evaluation center<\/h2>\n\n\n\n<p>FINECS has introduced a wide range of analytical instruments and constantly maintains stable levels of quality. Our analytical capabilities and high quality are highly regarded by our customers. We can also undertake various types of analysis work, so please feel free to contact us.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">System that enables optimal proposals based on data<\/h3>\n\n\n\n<p>In recent years, with the ultra-miniaturization of electronic components, the quality demands required by various materials constituting products, surface conditions of products, the entire product, etc., have become stricter every day.<br>From the viewpoint of quality control and environmental management, we have introduced the latest analytical instruments to enhance our analytical capabilities and analytical capabilities, and have established a system that enables our customers to use FINECS Group products with confidence.<br>Using the Basic Quality Control Method, we will deepen our analytical capabilities and analytical capabilities day by day, and propose optimal solutions based on data.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-default\"\/>\n<\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">List of analytical instruments<\/h2>\n\n\n\n<h3 class=\"heading-content wp-block-heading\">Analyzer<\/h3>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"title-content\">Scanning electron microscope<\/p>\n\n\n\n<div class=\"wp-block-columns col-2 is-layout-flex wp-container-9 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:45%\">\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" loading=\"lazy\" src=\"http:\/\/133.125.84.183\/wp\/wp-content\/uploads\/2023\/08\/\u8a55\u4fa1\u30bb\u30f3\u30bf\u30fc_\u8d70\u67fb\u578b\u96fb\u5b50\u9855\u5fae\u93e1.png\" alt=\"\" class=\"wp-image-8557\" width=\"555\" height=\"331\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-table\">\n    <table>\n        <tbody>\n            <tr>\n                <td style=\"white-space: nowrap; font-size: 14px;\">Equipment<br>manufacturer<\/td>\n                <td style=\"font-size: 14px;\">JEOL<\/td>\n            <\/tr>\n            <tr>\n                <td style=\"font-size: 14px;\">Main applications<\/td>\n                <td style=\"font-size: 14px;\">Surface observation (high vacuum, low vacuum) and elemental analysis<\/td>\n            <\/tr>\n        <\/tbody>\n    <\/table>\n<\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<div class=\"wp-block-columns is-layout-flex wp-container-4 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"font-size:20px\">\n<p class=\"has-regular-font-size\">The sample is irradiated with an electron beam to detect reflected electrons from the surface or electrons generated by excitation, and the surface of the substance is observed. Surface observation from low to several tens of thousand times is possible, and qualitative quantitative analysis of minute areas is possible at the same time as observation.<br>Elemental analysis is X-ray spectroscopy using an energy dispersive X-ray spectrometer, and the analysis element range is B to U, and simultaneous analysis of the whole element range is possible.<\/p>\n\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" src=\"http:\/\/133.125.84.183\/wp\/wp-content\/uploads\/2023\/08\/\u8a55\u4fa1\u30bb\u30f3\u30bf\u30fc_SEM\u30de\u30c3\u30d4\u30f3\u30b0.png\" alt=\"\" class=\"wp-image-8558\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" src=\"http:\/\/133.125.84.183\/wp\/wp-content\/uploads\/2023\/08\/\u8a55\u4fa1\u30bb\u30f3\u30bf\u30fc_\u8868\u9762\u89b3\u5bdf.png\" alt=\"\" class=\"wp-image-8559\"\/><\/figure>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"title-content\">High-frequency induction plasma emission spectrometer<\/p>\n\n\n\n<div class=\"wp-block-columns col-2 is-layout-flex wp-container-18 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:45%\">\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" loading=\"lazy\" src=\"http:\/\/133.125.84.183\/wp\/wp-content\/uploads\/2023\/07\/evaluationcenter-img01.png\" alt=\"\" class=\"wp-image-7962\" width=\"503\" height=\"313\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-table has-small-font-size\"><table><tbody><tr><td>Equipment manufacturer<\/td><td>SHIMADZU<\/td><\/tr><tr><td>Main applications<\/td><td>Quantitative elemental analysis of solution samples<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<div class=\"wp-block-columns is-layout-flex wp-container-16 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-regular-font-size is-layout-flow wp-block-column-is-layout-flow\">\n<p>High-temperature plasma is generated by ionizing argon gas using high frequency. When a liquid sample is sucked into the plasma and introduced into the plasma, the element-specific light generated from the excited atoms is detected spectroscopically for qualitative and quantitative analysis of the elements. Our equipment is a ICP emission spectrophotometer that is equipped with two sequential-type spectrometers and achieves both high resolution and high speed in comparison with the multi-element simultaneous analysis type (multi-channel type).<\/p>\n\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-14 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" src=\"http:\/\/133.125.84.183\/wp\/wp-content\/uploads\/2023\/08\/\u8a55\u4fa1\u30bb\u30f3\u30bf\u30fc_\u9ad8\u5468\u6ce2\u8a98\u5c0e\u30d7\u30e9\u30ba\u30de.png\" alt=\"\" class=\"wp-image-8560\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"title-content\">Fourier transform infrared spectrophotometer<\/p>\n\n\n\n<div class=\"wp-block-columns col-2 is-layout-flex wp-container-27 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:45%\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"http:\/\/133.125.84.183\/wp\/wp-content\/uploads\/2023\/08\/\u8a55\u4fa1\u30bb\u30f3\u30bf\u30fc_\u9ad8\u5468\u6ce2\u8a98\u5c0e\u30d7\u30e9\u30ba\u30de\u767a\u5149\u5206\u6790\u88c5\u7f6e-icps-8100-1-1.png\" alt=\"\" class=\"wp-image-8561\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-table has-small-font-size\"><table><tbody><tr><td>Equipment manufacturer<\/td><td>SHIMADZU<\/td><\/tr><tr><td>Main applications<\/td><td>Estimation of organic compounds (qualitative)<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<div class=\"wp-block-columns is-layout-flex wp-container-22 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-regular-font-size is-layout-flow wp-block-column-is-layout-flow\">\n<p>An analytical device that performs structural estimation (qualitative) of mainly organic compounds. Irradiated infrared light from the light source is directed onto the sample to absorb infrared radiation, which is equivalent to the vibrational energy inherent in the molecules (interatomic). The degree of absorption = The degree of interference is detected, and the structure of the compound can be analyzed by Fourier transform. Surface structure can be analyzed by infrared microscopy.<\/p>\n\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-25 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" src=\"http:\/\/133.125.84.183\/wp\/wp-content\/uploads\/2023\/08\/\u8a55\u4fa1\u30bb\u30f3\u30bf\u30fc_\u30d5\u30fc\u30ea\u30a83.png\" alt=\"\" class=\"wp-image-8701\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"title-content\">Energy-dispersive X-ray fluorescence spectrometers<\/p>\n\n\n\n<div class=\"wp-block-columns col-2 is-layout-flex wp-container-36 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:45%\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"http:\/\/133.125.84.183\/wp\/wp-content\/uploads\/2023\/08\/\u8a55\u4fa1\u30bb\u30f3\u30bf\u30fc_\u30a8\u30cd\u30eb\u30ae\u30fc\u5206\u6563-1024x610.png\" alt=\"\" class=\"wp-image-8752\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-table has-small-font-size\"><table><tbody><tr><td>Equipment manufacturer<\/td><td>SHIMADZU<\/td><\/tr><tr><td>Main applications<\/td><td>Quantitative analysis of elements in various sample forms, including metals, resins, powders, and liquids<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<div class=\"wp-block-columns is-layout-flex wp-container-31 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-regular-font-size is-layout-flow wp-block-column-is-layout-flow\">\n<p>\u8a66\u6599\u306bX\u7dda\u3092\u7167\u5c04\u3057\u3066\u3001\u305d\u3053\u304b\u3089\u767a\u751f\u3059\u308b\u86cd\u5149X\u7dda\uff082\u6b21X\u7dda\uff09\u306e\u30a8\u30cd\u30eb\u30ae\u30fc\u3068\u5f37\u5ea6\u304b\u3089\u5143\u7d20\u306e\u7279\u5b9a\uff08\u5b9a\u6027\uff09\u3068\u5b9a\u91cf\u5206\u6790\u3092\u884c\u306a\u3044\u307e\u3059\u3002\u8584\u819c\u3001\u3081\u3063\u304d\u76ae\u819c\u7b49\u306e\u819c\u539a\u6e2c\u5b9a\u3082\u53ef\u80fd\u3002RoHS\u5bfe\u5fdc\u3002<\/p>\n\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-34 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"http:\/\/133.125.84.183\/wp\/wp-content\/uploads\/2023\/08\/A750\u30b9\u30da\u30af\u30c8\u30eb2-1024x669.png\" alt=\"\" class=\"wp-image-8758\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"http:\/\/133.125.84.183\/wp\/wp-content\/uploads\/2023\/08\/PF\u7aef\u5b50\u30b9\u30da\u30af\u30c8\u30eb-1024x667.png\" alt=\"\" class=\"wp-image-8759\"\/><\/figure>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-default\"\/>\n\n\n\n<h3 class=\"heading-content wp-block-heading\">Environmental load device<\/h3>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"title-content\">Temperature (cold) impact tester<\/p>\n\n\n\n<div class=\"wp-block-columns col-2 is-layout-flex wp-container-45 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:45%\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"http:\/\/133.125.84.183\/wp\/wp-content\/uploads\/2023\/08\/\u8a55\u4fa1\u30bb\u30f3\u30bf\u30fc_TSA-103ESTSA-103EL-1.png\" alt=\"\" class=\"wp-image-8563\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-table has-small-font-size\"><table><tbody><tr><td>Equipment manufacturer<\/td><td>Espec<\/td><\/tr><tr><td>Main applications<\/td><td>Environmental assessment equipment (SH) and thermal shock equipment (TSA)<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<div class=\"wp-block-columns is-layout-flex wp-container-40 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-regular-font-size is-layout-flow wp-block-column-is-layout-flow\">\n<p>[Small Environmental Test Equipment SH]<br>\u3000Characterization can be performed in the range from low temperature (-70\u00b0C) to high temperature (-200\u00b0C). which is the basis for various development tests, quality assurance, and reliability tests.<br>[Cold thermal shock device]<br>\u3000The thermal shock test is a test to evaluate the reliability of the product by alternately giving high temperature (+150\u00b0C) and low temperature (-60\u00b0C) in a short time. Expansion and contraction with temperature changes cause repeated stress to accumulate material fatigue, which may lead to fracture at a strength lower than the static strength, and is used for data analysis at the design and development stage.<\/p>\n\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-43 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" src=\"http:\/\/133.125.84.183\/wp\/wp-content\/uploads\/2023\/08\/\u8a55\u4fa1\u30bb\u30f3\u30bf\u30fc_TSA1.png\" alt=\"\" class=\"wp-image-8564\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" src=\"http:\/\/133.125.84.183\/wp\/wp-content\/uploads\/2023\/08\/\u8a55\u4fa1\u30bb\u30f3\u30bf\u30fc_TSA2.png\" alt=\"\" class=\"wp-image-8565\"\/><\/figure>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<h3 class=\"heading-content wp-block-heading\">Measuring instrument<\/h3>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"title-content\">Fluorescent X-ray film thickness estimation equipment\u3000<\/p>\n\n\n\n<div class=\"wp-block-columns col-2 is-layout-flex wp-container-55 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:45%\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"http:\/\/133.125.84.183\/wp\/wp-content\/uploads\/2023\/08\/\u8a55\u4fa1\u30bb\u30f3\u30bf\u30fc_FT150.png\" alt=\"\" class=\"wp-image-8566\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-table has-small-font-size\"><table><tbody><tr><td>Equipment manufacturer<\/td><td>HITACHI<\/td><\/tr><tr><td>Main applications<\/td><td>Film thickness measurement of known elements such as plating film<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<div class=\"wp-block-columns is-layout-flex wp-container-50 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-regular-font-size is-layout-flow wp-block-column-is-layout-flow\">\n<p>X-rays are irradiated on the sample, and the film thickness is converted from the intensity of the fluorescent X-rays (secondary X-rays) generated from there. The film thickness is calculated from a calibration curve using a standard sample. In recent years, connectors are becoming stronger in pitch, and microscopic terminals are becoming the mainstream. In addition, high-precision measurement methods are desired to save money. FT150 employs a polycapillary to collect X-rays and has an X-ray radiation diameter of \u03c630\u03bcm, making it a high-performance machine that can measure the plating film thickness of minute parts at high speed with high accuracy. Thin-film FP and calibration curve methods can be selected as the measuring modes. However, we use the calibration curve method.<\/p>\n\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-53 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" src=\"http:\/\/133.125.84.183\/wp\/wp-content\/uploads\/2023\/08\/\u8a55\u4fa1\u30bb\u30f3\u30bf\u30fc_FT150_2.png\" alt=\"\" class=\"wp-image-8567\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"title-content\">Microscope\u3000<\/p>\n\n\n\n<div class=\"wp-block-columns col-2 is-layout-flex wp-container-66 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:45%\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"http:\/\/133.125.84.183\/wp\/wp-content\/uploads\/2023\/08\/\u30de\u30a4\u30af\u30ed\u30b9\u30b3\u30fc\u30d7-1024x819.png\" alt=\"\" class=\"wp-image-8737\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-table has-small-font-size\"><table><tbody><tr><td>Equipment manufacturer<\/td><td>KEYENCE<\/td><\/tr><tr><td>Main applications<\/td><td>Surface observation, measurement, photography, data analysis<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<div class=\"wp-block-columns is-layout-flex wp-container-60 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-regular-font-size is-layout-flow wp-block-column-is-layout-flow\">\n<p>Due to its excellent resolution and wide magnification range, it is used for fine observation and data analysis of the measured object.<\/p>\n\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-64 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"http:\/\/133.125.84.183\/wp\/wp-content\/uploads\/2023\/08\/\u30db\u30fc\u30e0\u30da\u30fc\u30b8\u7528\u5199\u771f-1-1024x768.jpg\" alt=\"\" class=\"wp-image-8762\"\/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"title-content\">Image size measuring instrument\u3000<\/p>\n\n\n\n<div class=\"wp-block-columns col-2 is-layout-flex wp-container-75 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:45%\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"http:\/\/133.125.84.183\/wp\/wp-content\/uploads\/2023\/08\/\u8a55\u4fa1\u30bb\u30f3\u30bf\u30fc_\u753b\u50cf\u5bf8\u6cd5\u6e2c\u5b9a\u5668-1024x610.png\" alt=\"\" class=\"wp-image-8753\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-table has-small-font-size\"><table><tbody><tr><td>Equipment manufacturer<\/td><td>KEYENCE<\/td><\/tr><tr><td>Main applications<\/td><td>Measurement of product dimensions<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<div class=\"wp-block-columns is-layout-flex wp-container-70 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-regular-font-size is-layout-flow wp-block-column-is-layout-flow\">\n<p>Automatically measures pre-programmed measurement points at a higher speed and more accurately than the captured image.<\/p>\n\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-73 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"http:\/\/133.125.84.183\/wp\/wp-content\/uploads\/2023\/08\/\u753b\u50cf\u5bf8\u6cd5\u6e2c\u5b9a\u5668\u30b5\u30d6.jpg\" alt=\"\" class=\"wp-image-8763\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"title-content\">List of in-house inspection equipment<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n  <table class=\"freeze-row\">\n    <tbody>\n      <tr>\n        <td><\/td>\n        <td>Name of equipment<\/td>\n        <td>Equipment manufacturer<\/td>\n      <\/tr>\n      <tr>\n        <td rowspan=\"7\">Analyzer<\/td>\n        <td>Scanning electron microscopy (SEM)<\/td>\n        <td>JEOL<\/td>\n      <\/tr>\n      <tr>\n        <td>High-frequency induction plasma emission spectrometer<\/td>\n        <td>SHIMADZU<\/td>\n      <\/tr>\n      <tr>\n        <td>Fourier transform infrared spectrophotometer<\/td>\n        <td>SHIMADZU<\/td>\n      <\/tr>\n        <td>Energy-dispersive X-ray fluorescence spectrometers<\/td>\n        <td>SHIMADZU<\/td>\n      <\/tr>\n      <tr>\n        <td>Total organic carbon meter (high-sensitivity type)<\/td>\n        <td>SHIMADZU<\/td>\n      <\/tr>\n      <tr>\n        <td>Atomic absorption spectrophotometer<\/td>\n        <td>SHIMADZU<\/td>\n      <\/tr>\n      <tr>\n        <td>Spectrophotometer (UV-visible)<\/td>\n        <td>SHIMADZU<\/td>\n      <\/tr>\n      <tr>\n        <td rowspan=\"4\">Environmental load device<\/td>\n        <td>Temperature (cold) impact tester<\/td>\n        <td>Espec<\/td>\n        <\/tr>\n      <tr>\n        <td>Highly accelerated life tester<\/td>\n        <td>Hirayama Manufacturing<\/td>\n      <\/tr>\n      <tr>\n        <td>Constant temperature and high temperature dryer<\/td>\n        <td>EYELA<\/td>\n      <\/tr>\n      <tr>\n        <td>Thermostatic bath<\/td>\n        <td>Espec<\/td>\n      <\/tr>\n      <tr>\n        <td rowspan=\"17\">Measuring instrument<\/td>\n        <td>Fluorescent X-ray film thickness measuring device<\/td>\n        <td>HITACHI<\/td>\n        <\/tr>\n      <tr>\n        <td>Microscope<\/td>\n        <td>KEYENCE<\/td>\n      <\/tr>\n      <tr>\n        <td>Height and flatness measuring instrument<\/td>\n        <td>KEYENCE<\/td>\n      <\/tr>\n      <tr>\n        <td>Image size measuring instrument<\/td>\n        <td>KEYENCE<\/td>\n      <\/tr>\n      <tr>\n        <td>Cross-sectional material preparation equipment<\/td>\n        <td>JEOL<\/td>\n      <\/tr>\n      <tr>\n        <td>Micro Vickers hardness tester<\/td>\n        <td>ARS<\/td>\n      <\/tr>\n      <tr>\n        <td>Micro Vickers hardness tester<\/td>\n        <td>SHIMADZU<\/td>\n      <\/tr>\n      <tr>\n        <td>Precision universal tester<\/td>\n        <td>SHIMADZU<\/td>\n      <\/tr>\n      <tr>\n        <td>Solder checker<\/td>\n        <td>RHESCA<\/td>\n      <\/tr>\n      <tr>\n        <td>Compressive tensile testing machine<\/td>\n        <td>-<\/td>\n      <\/tr>\n      <tr>\n        <td>Stereomicroscope<\/td>\n        <td>-<\/td>\n      <\/tr>\n      <tr>\n        <td>Measuring microscope<\/td>\n        <td>-<\/td>\n      <\/tr>\n      <tr>\n        <td>Automatic measuring equipment<\/td>\n        <td>Nikon<\/td>\n      <\/tr>\n      <tr>\n        <td>Projector<\/td>\n        <td>Nikon<\/td>\n      <\/tr>\n      <tr>\n        <td>Glossmeter<\/td>\n        <td>Nippon Denshoku Industries<\/td>\n      <\/tr>\n      <tr>\n        <td>Electronic scale<\/td>\n        <td>-<\/td>\n      <\/tr>\n      <tr>\n        <td>Electric furnace<\/td>\n        <td>SHIMADZU<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n<\/figure>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Have credible analytical and analytical powerEvaluation center FINECS has introduced a wide range of analytical instruments and constantly maintains stable levels of quality. Our analytical capabilities and high quality are highly regarded by our customers. We can also undertake various types of analysis work, so please feel free to contact us. System that enables optimal...<\/p>\n","protected":false},"author":1,"featured_media":5102,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_lmt_disableupdate":"","_lmt_disable":"","footnotes":""},"acf":[],"_links":{"self":[{"href":"http:\/\/133.125.84.183\/en\/wp-json\/wp\/v2\/pages\/5099"}],"collection":[{"href":"http:\/\/133.125.84.183\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/133.125.84.183\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/133.125.84.183\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/133.125.84.183\/en\/wp-json\/wp\/v2\/comments?post=5099"}],"version-history":[{"count":7,"href":"http:\/\/133.125.84.183\/en\/wp-json\/wp\/v2\/pages\/5099\/revisions"}],"predecessor-version":[{"id":5474,"href":"http:\/\/133.125.84.183\/en\/wp-json\/wp\/v2\/pages\/5099\/revisions\/5474"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/133.125.84.183\/en\/wp-json\/wp\/v2\/media\/5102"}],"wp:attachment":[{"href":"http:\/\/133.125.84.183\/en\/wp-json\/wp\/v2\/media?parent=5099"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}